OFFICE SCHOOL HOSPITAL FIRE SYSTEM

Fire Extinguisher

W-CO2 FIRE EXTINGUISHER: Our range of water type fire extinguisher are suitable for Class A fire. These are used to fight against fire, which involve combustible material of organic nature like wood, paper, textile, jute etc.

img

DCP FIRE EXTINGUISHER

Oil, Solvents, Gases, Paints Varnish, Electrical Wiring, Live Machinery Fire, All flammable liquid and fires

img

CO2 FIRE EXTINGUISHER

Useful for class 'B' & 'C' fires involving materials like fabric, oil spillages and delicate machineries. CO2 extinguishers fire by blanketing dilution of oxygen and cooling effects. B.I.S. Specification: 2878

img

ABC FIRE EXTINGUISHER

This ABC fire extinguisher is useful for fires of class A, B & C types which involve wood, cotton, flammable liquids, grease, electrical wiring, live machineries etc. The blanketing effect of ABC powder decomposes fire quickly. B.I.S. Specification: 13849

DOWN COMER SYSTEM

img

Hydrant system

It is a well-designed & well laid hydrant system which extinguish fires of serious proportions in all classes of risks. It has the ability to continues to be in full operation even if part (s) of affected buildings &/ or structures have collapsed & also keeps cool all adjoining properties. It is also a part of hydrant system to provide a pipe permanently charged with water under pressure rising through the full height of the building.

Sprinkler system

Sprinkler system is most popular system because of it’s vide applications in fire industries. It has two function to perform firstly, it detect a fire and they provide an adequate of water spray only over the vicinity of fire.

Application

Industrial/non industrial buildings, institutional buildings, residential apartments, hotel & hospitals, mall & multi storied complexes, chemical & flammable storage yards

WET RISER SYSTEMS

The wet riser systems are permanently charged with water from a header tank above the wet riser system and will be automatically discharged in an event of an outbreak of fire.
The main difference between wet and dry risers is that dry risers systems can only be installed up to 60 metres and are not pressurised with water like wet risers.
Wet riser systems are the pipework system that will carry water to the sprinkler heads in case of a fire. Sprinkler systems are the most reliable and simple as the only operating components being the automatic sprinklers and the automatic alarm check valve. An automatic water supply provides water under pressure to the system piping. All of the piping is filled with water. Until sufficient heat is applied, causing one or more sprinklers to fuse, the automatic sprinklers prevent the water from being discharged.

img

Wet riser systems are a building regulations requirement in occupied buildings over 60 metres tall and form part of a buildings fire suppression system.

img

FIRE DETECTION SYSTEM